3. System architecture
3.1. Typical architecture example
3.1.1. Figure - typical architecture example
3.1.2. Typical architecture - Schochman SD10 - MFD
The Schochman SD10 configured as the MFD (Multi-Function Display) connects to the Schochman CAN-bus via connector DSUB-1 to exchange data with the rest of the ecosystem. For multi-display operation and optional internet connectivity, the MFD connects to the aircraft Ethernet switch via its RJ-45 Ethernet port (shielded twisted pair recommended). The Ethernet network is used for PFD↔MFD communication and for any network-based accessories shown in the architecture diagram.
3.1.3. Typical architecture - Schochman SD10 - PFD
The Schochman SD10 configured as the PFD (Primary Flight Display) is the pilot’s primary source of attitude/flight information and primary user interaction. Like the MFD, it connects to the CAN-bus via connector DSUB-1 and to the Ethernet switch via connector ETHERNET. Note that in multi-EFIS installations an Ethernet switch is required; direct point-to-point Ethernet wiring between EFIS units is not supported.
In this example, the PFD also hosts a Schochman ADS-B receiver module via a rear USB expansion port (Schochman-approved modules only).
For audio, connector DSUB-2 provides the SD10 headset audio interface (MIC± / SPK±). In this architecture, the speaker output is routed to the radio/intercom auxiliary input to play EFIS alerts/annunciations into the headset system. The microphone input is “tapped” from the pilot microphone line using the MIC ISOLATION circuit (below) so the EFIS can support voice/AI features without disturbing the normal radio mic path. Keep in mind that MIC− and SPK− are not ground (differential audio) and must not be tied to airframe ground.
3.1.4. Typical architecture - MIC ISOLATION
MIC ISOLATION is used to provide the EFIS (and/or AI/voice features) access to the pilot microphone signal while keeping the radio microphone path electrically safe and stable. The goal is to avoid loading the microphone circuit, introducing noise, or creating a failure mode that could affect communications.
Use the recommended MIC ISOLATION schematic shown in section 4.4.1.1. Figure - Electrical installation - audio wiring example. If the aircraft uses an audio panel/intercom with a dedicated auxiliary audio interface, that interface may provide an alternative, cleaner integration point—refer to the relevant equipment documentation and the specific Schochman device manuals for supported options.
3.1.5. Typical architecture - SCHOCHMAN AI COMPUTER
The Schochman AI Computer is an optional networked module intended for live AI/voice functionality (e.g., ATC/audio analysis features, depending on software configuration). It connects to the Ethernet switch to communicate with the EFIS.
Its audio input can be connected directly to the Pilot's headset speaker positive pin
3.1.6. Typical architecture - ETHERNET SWITCH
The Ethernet switch forms the Local Area Network (LAN) for the Schochman system. It enables:
PFD↔MFD communication
Communication with network accessories (AI computer, IP camera, etc.)
Optional internet access when an external uplink is connected (e.g., Starlink)
A switch is required because direct EFIS-to-EFIS Ethernet connections are not supported.
3.1.7. Typical architecture - STARLINK ANTENNA
The Starlink antenna provides an optional internet uplink for the onboard Ethernet network. For reliable operation, install the antenna with an appropriate view of the sky and avoid mounting locations where conductive materials (metal structures, carbon layers, etc.) significantly obstruct the antenna. In this example, Starlink Mini is used.
(Internet connectivity is optional—core EFIS and CAN-bus functions remain independent of it.)
3.1.8. Typical architecture - IP CAMERA
The IP camera is connected to the LAN through the Ethernet switch. The video stream can be displayed on the PFD/MFD and may be used as a situational-awareness aid or as an optional background/source where supported by software configuration (e.g., camera view pages).
3.1.9. Typical architecture - ADSB RECEIVER
The Schochman ADS-B receiver provides traffic data to the EFIS for display and alerting (subject to system configuration and regional rules). In this architecture it is connected to the SD10 via a rear USB expansion port intended for Schochman-approved expansion modules.
3.1.10. Typical architecture - SCHOCHMAN DATAHUB
The Schochman Datahub acts as the integration bridge between the Schochman CAN ecosystem and supported third-party avionics devices. It connects to the Schochman CAN-bus and provides dedicated RS-232 interfaces for supported equipment (currently the f.u.n.k.e. ATR833-II radio and TRT800H-OLED transponder).
The Datahub also provides a joystick/grip input interface for pilot/copilot controls. These inputs are discrete (switch-to-ground) signals intended for aviation stick grips or other button panels, enabling EFIS interaction without touching the screen.
3.1.11. Typical architecture - VHF Radio f.u.n.k.e. ATR833-II
The f.u.n.k.e. ATR833-II VHF radio is the currently supported radio for remote control via the Schochman system. Through the RS-232 link (via the Datahub), the EFIS can command functions such as frequency selection and mode control, depending on software features enabled.
The aircraft headset microphone and headphone audio remain primarily routed through the radio/intercom system. The EFIS audio output has to be connected to a suitable auxiliary audio input to play alerts/annunciations into the headset system (as shown in the diagram).
3.1.12. Typical architecture - Transponder f.u.n.k.e. TRT800H-OLED
The f.u.n.k.e. TRT800H-OLED transponder is the currently supported transponder for remote control via the Schochman system. Through the RS-232 link (via the Datahub), the EFIS can support functions such as squawk entry and mode changes, depending on software features enabled.
3.1.13. Typical architecture - SCHOCHMAN AHRS
The Schochman AHRS (Attitude and Heading Reference System) provides the core sensor data required for flight instruments, including attitude, air data (via pitot/static/AOA), GNSS position/velocity, and outside air temperature (when connected). It connects to the Schochman CAN-bus to publish sensor data to the EFIS units.
Correct pneumatic plumbing is critical—STATIC/PITOT/AOA lines must be connected to the correct ports and routed leak-free to avoid invalid or hazardous indications.
3.1.14. Typical architecture - SCHOCHMAN FLAPS CONTROLLER
The Schochman Flaps Controller provides control of a DC flaps actuator and enables EFIS-integrated flap position indication and detents. It is connected to the Schochman CAN-bus, allowing the EFIS to command flap positions and display the current flap state.
Flap positions are configured/calibrated through the EFIS user interface (overview only here—see the Flaps Controller manual for the calibration procedure).
3.1.15. Typical architecture - SCHOCHMAN ENGINE MONITORING SYSTEM
The Schochman Engine Monitoring System (EMS) collects and publishes engine and airframe sensor data to the EFIS over the Schochman CAN-bus. In this example it is connected to a Rotax 912 iS ECU using both ECU CAN lanes (A and B) to support Rotax’s dual-lane architecture .
The EMS can also accept additional analog/digital sensors (e.g., fuel quantity/pressure, temperatures, electrical measurements) when such parameters are not available via the ECU data stream.
3.1.16. Typical architecture - AUTOPILOT SERVOS
In this architecture, two MGL Avionics autopilot servos (ROLL and PITCH) are connected to the system to provide autopilot capability. The servos are mechanically connected to aircraft controls and communicate over the avionics network as supported by the EFIS/autopilot configuration.
Refer to the autopilot servo manufacturer documentation and the relevant Schochman autopilot guidance for configuration and limitations.
3.1.17. Typical architecture - SHOCHMAN MAGNETIC COMPASS
The Schochman Magnetic Compass (magnetometer module) provides magnetic heading information to the Schochman ecosystem via the CAN-bus. Because magnetometers are sensitive to local magnetic disturbances, the unit must be installed using appropriate practices: keep it away from ferrous structures, high-current wiring, speakers, motors/actuators, and use non-magnetized tools during installation.