4. Electrical installation
4.1. Power
The EFIS is designed to operate from a standard 12 V aircraft electrical system and supports a 9–28 V DC input range.
Power is supplied through two independent power input pins (Connector DSUB-1):
BAT_P – Primary power input
BAT_S – Secondary power input
Both inputs are electrically equivalent. The system is designed to support use cases such as:
Main bus + backup battery
Dual independent batteries
Single power source connected to either input
No user action or configuration is required to manage power source selection.
4.2. Protection
Each EFIS unit must be protected by its own dedicated circuit breaker. Power protection shall be installed as close as practical to the aircraft power distribution bus.
Recommended protection:
Circuit breaker:
Type: Thermal or thermal-magnetic
Recommended rating: 10 A per SD-10
One breaker per EFIS unit (do not share with other equipment)
4.3. Wiring
The EFIS communicates with external devices and expansion modules using a CAN (Controller Area Network) bus. All Schochman devices use a common CAN bus architecture and follow standard CAN physical-layer rules.
4.3.1. CAN-bus topology and termination
4.3.1.1. Figure - CAN-bus topology example
The Schochman EFIS CAN bus must be wired using a linear backbone (bus) topology.
Wiring rules:
One continuous backbone cable
Exactly two termination resistors (120 Ω) — one at each physical end of the backbone
Devices connected via short stub lines
Total bus impedance must measure approx. 60 Ω between CAN-H and CAN-L (power off)
Cable requirements:
Twisted pair cable (minimum 1 twist per 25 mm)
Recommended wire size: 22–24 AWG
Shielded twisted pair recommended in high-noise environments
4.3.1.2. Figure - Non end device CAN-BUS connection
The device is connected to the main CAN backbone using a short CAN STUB (drop line) connection. The backbone must remain continuous.
Installation Rules
The device must NOT have termination enabled
The backbone cable must not be interrupted by star connections
The stub connection must be kept as short as possible
Maximum CAN STUB length: 0.5 m
Stub length is defined as the total cable length between the backbone splice point and the device connector.
Exceeding this length may result in:
Reflections on the bus
Intermittent communication errors
Increased error frames
Unstable system behavior
Shorter stub lengths (< 0.3 m) are strongly recommended.
4.3.1.3. Figure - End device CAN-BUS connection
This example shows the connection of a device located at the physical end of the CAN backbone. In this configuration, the device provides one of the two required CAN bus termination resistors. Termination resistor must be connected directly between CAN-H and CAN-L. Only two termination resistors are allowed in the entire CAN network. The second 120 Ω termination resistor must be installed at the opposite physical end of the backbone.
Important Rules
Termination must be installed only at the two extreme ends of the backbone
No stub is used for an end device — the backbone ends at this device
No additional devices may be connected beyond this point
4.3.2. Cable requirements
For reliable operation in the aircraft environment, the CAN bus shall be wired using aviation-grade twisted-pair cable.
Recommended cable characteristics:
Twisted pair for CAN_H and CAN_L
High-temperature insulation suitable for aircraft use
Flame-retardant and low-smoke materials
Mechanical robustness suitable for vibration environments
A shielded, aviation-certified cable with proven resistance to heat, vibration, and fire is strongly recommended. Use of high-quality aircraft wiring significantly improves noise immunity and long-term reliability of the CAN bus.
4.4. Audio
The EFIS provides a basic analog audio interface for connection to an aviation headset.
Available audio signals:
SPK+ / SPK− – Headphone (speaker) output
MIC+ / MIC− – Microphone input
Both speaker and microphone connections use differential (balanced) signaling.
When a Schochman external audio module is installed, the internal audio interface is not used and SPK+ / SPK− and MIC+ / MIC− pins shall be left unconnected. Audio routing is handled exclusively by the external audio module in that case.
Wiring Recommendations
Use shielded twisted-pair cable for all audio signals
Keep audio wiring separated from power and high-current cables
4.4.1. Electrical installation - audio wiring example
4.4.1.1. Figure - Electrical installation - audio wiring example
Schematic represents typical audio installation in the aircraft with one Schochman SD10 configured as PFD. Only audio relevant pins are shown in the figure, note that other functional pins like power for devices or can bus still must be wired. Audio wiring consists of standard headsets to VHF radio direct connections. Schochman SD10 reuse pilots microphone input via MIC-ISOLATION that is further used to Voice control of the system. Schochman SD10 audio output is connected to specific radio input for efis alert sounds. To allow remote control of VHF radio, its RS232 pins are connected to Schochman DATAHUB.
The schematic represents a typical aircraft audio installation with one Schochman SD10 configured as the PFD. Only audio-related pins are shown in the figure. All other required connections (power supply, CAN-bus, etc.) must be wired in accordance with their respective sections of the manuals.
In this example:
The pilot and copilot headsets are connected directly to the VHF radio/intercom system in the standard configuration.
The Schochman SD10 reuses the pilot microphone signal via the MIC-ISOLATION circuit. This allows the EFIS to access the microphone audio (e.g., for voice/AI features) without electrically loading or disturbing the primary radio microphone path.
The EFIS audio output (SPK+ / SPK−) is connected to a suitable auxiliary audio input (e.g., EXT-NF or equivalent) of the VHF radio or audio panel in order to inject EFIS alerts and annunciations into the headset system.
For remote radio control, the radio RS-232 interface is connected to the Schochman DATAHUB.
Audio Signal Characteristics
SPK+ / SPK− and MIC+ / MIC− are differential (balanced) audio signals.
SPK− and MIC− are not ground and must not be connected to airframe ground.
Do not tie any audio return conductor to aircraft chassis unless explicitly required by the connected equipment documentation.
Improper grounding or tying negative audio lines to chassis ground may result in:
Audio distortion
Ground loops
Noise injection
Potential damage to audio stages
MIC Isolation Circuit
The MIC-ISOLATION network ensures:
High input impedance toward the radio microphone circuit
No degradation of radio transmission quality
Fail-safe behavior (radio remains operational if EFIS is powered off or disconnected)
The installer shall:
Use the exact component values shown in the schematic
Install the circuit physically close to the radio/intercom side when practical
Ensure proper shielding of microphone wiring
Wiring Recommendations
Use shielded twisted-pair cable for:
SPK+ / SPK−
MIC+ / MIC−
Connect shield to ground at one end only (preferably at the radio/audio panel side) to avoid ground loops.
Keep audio wiring separated from:
Power supply cables
Strobe wiring
Alternator output wiring
High-current actuator wiring
Avoid running audio cables parallel to high-current lines for extended distances.