13. Servo flaps

This chapter configures the Schochman Flaps Controller and checks its operation on the ground. Complete Initial installation, actuator mounting, linkage and motor/position-feedback wiring first. Use the aircraft’s installation information for every flap angle and mechanical clearance; no universal angles are specified here.

Keep the engine stopped and the flap mechanism clear. Before powered movement, know how to stop the actuator safely using the installation’s controls. With tandem displays, configure the shared controller once, using one display at a time. Verify the returned settings and indications on both displays afterwards.

13.1. Confirm detection and firmware

Open: MORE / SETTINGS / CONFIGURATION / HARDWARE. Find Flaps Controller / Schochman Flaps Controller. If necessary, select that model. Green ONLINE or a green SNxxxxxx indicates communication; a serial number replaces ONLINE when available. Resolve OFFLINE before proceeding.

HARDWARE row with Schochman Flaps Controller selected and a synthetic green serial SN100008.

UI illustration: detected flaps controller. The serial number is fictional.

Open: MORE / SETTINGS / UPDATES / DEVICES UPDATE. Use the Flaps row. Internet access and login are required for downloading firmware.

  1. Read the installed firmware v…. When an update is available, select UPDATE, then confirm Update and Confirm. Update only on the ground.

  2. Keep the controller and display powered through transfer and controller restart. Upload complete – waiting for device restart is intermediate.

  3. Wait for the controller to return and verify its reported installed version and HARDWARE detection. Recheck calibration and ground operation afterwards. With tandem displays, update once and verify reception on both.

Four synthetic Flaps update states: installed firmware, upload progress, waiting for restart, and the returned controller reporting a new version.

UI illustrations: firmware update stages. Versions 1.0.0 and 1.0.1 are fictional examples, not a statement of available releases.

Firmware already up to date means no update is needed. A disabled UPDATE button alone does not confirm this; resolve offline, busy or error states.

13.2. Select positions and check travel

Open: MORE / SETTINGS / CONFIGURATION / FLAPS SERVO SETUP. Wait for the controller’s settings to arrive. This installation currently supports exactly two position arrangements:

Arrangement

Required positions

Checkbox beside SET -1

Four positions

0, 1, 2, 3

Unchecked

Five positions

-1, 0, 1, 2, 3

Checked

Other position counts are not currently supported. -1, 0, 1, 2 and 3 are preset labels, not angles in degrees. Assign their physical positions according to the aircraft’s approved configuration. Enable -1 only when that position is required.

Cropped SET -1 rows comparing an unchecked disabled optional position for four presets with a checked enabled optional position for five presets.

UI illustrations: the two supported arrangements. The numerical values are synthetic feedback counts, not aircraft settings to copy.

13.2.1. Understand the ADC limits

ADC is the actuator’s position-feedback reading in counts. Calibration accepts values from 0 to 1023, but normal preset movement currently bounds its target to 50–850. A capture below 50 is commanded as 50; one above 850 is commanded as 850. The saved value itself is not corrected by this bound.

Before completing setup, confirm that every required aircraft position falls within 50–850, as well as within the aircraft’s permitted mechanical travel. These numbers are software feedback bounds, not recommended capture values or aircraft travel limits. If a required position falls outside that range, stop commissioning and have the installation reviewed; do not substitute a different flap angle just to fit the numbers.

Calibration jogging does not enforce the normal preset bounds. Watch the actual mechanism while using + / −, release before reaching a mechanical stop, and preserve the clearance specified for the installation. No universal margin is specified here.

13.3. Capture and verify calibration

Synthetic four-position calibration in progress, with SET -1 disabled, ADC 720, and calibrating 3/4 while the final preset has not yet been captured.

UI illustration: four-position calibration before the final capture. ADC values are fictional examples. The counter and screen do not establish actual movement.

  1. Select START CALIBRATION. If Flaps controller not responding appears, resolve communication first. Confirm a changing ADC reading is available during movement.

  2. Set the checkbox beside SET -1 for the required four- or five-position arrangement. Changing it is saved by the controller.

  3. Briefly hold + or −, release and confirm the actuator stops. Observe which physical direction each button produces; the signs are jog directions, not a guarantee of flap extension or retraction. If motion or feedback is incorrect, stop and resolve the installation before capturing positions.

  4. Jog to the aircraft-specified position 0, release, and check its physical angle and clearance. Select SET 0. Read back the numerical value returned by the controller in the adjacent field.

  5. Repeat for SET 1, SET 2 and SET 3, and SET -1 when enabled. Check every physical position and returned value. Normal preset commands and the controller’s flap switch are blocked during calibration.

  6. Confirm calibrating… 4/4 or calibrating… 5/5, as applicable. Select STOP CALIBRATION and confirm calibrated. Leaving the setup screen also exits calibration, but use the explicit stop step to finish the check.

13.3.1. Verify stored calibration

  1. Reopen the screen and compare every captured value and the -1 checkbox with the installation record. With tandem displays, read the same settings on the other display, without starting a second calibration.

  2. With the mechanism stopped, power-cycle the controller. Recheck detection, all captured values, the checkbox and calibrated status on each display.

Each capture is stored automatically in the controller’s EEPROM, and the controller returns the captured value. There is no separate Save button. Reopening reads the controller’s current settings; the power-cycle check verifies their retention. Replacing the controller requires calibration again; an SD-10 configuration profile does not restore this controller-held calibration.

Starting calibration preserves existing captures. During recalibration, a complete counter can remain complete while positions are being replaced. calibrated confirms that every required capture exists; it does not validate angles, spacing, ordering or mechanical reach. Verify every position even when the status already says calibrated. The numerical fields also permit direct editing during calibration; use the physical-position SET procedure above for normal setup.

13.4. Check normal operation and LEDs

Exit calibration before checking normal operation. Open the normal FLAPS control popup and command each enabled preset separately. Observe the actual flaps moving to the intended aircraft position, stopping and retaining mechanical clearance. Repeat through the positions in both directions.

The normal on-screen preset indication reports the selected target; it does not prove that the flaps have arrived. Check actual movement and diagnostics. Test the installed controller switch and any installed Datahub flap controls separately. Follow the Datahub flap rocker procedure to check its neutral and release behavior. With tandem displays, operate one display at a time and verify matching indications on both, together with actual flap response.

The controller’s LED strip provides these indications:

Indication

Meaning

Blue

An enabled position that is not the target or indicated current position

Green

Selected target position

Red at another position

Nearest calibrated position to the feedback reading

Flashing red

Fault or an uncalibrated movement request; target/current indications can remain visible

Disabled -1 LED off

The optional -1 position is not available

The red position indication is a nearest-preset indication, not an angle measurement. In the FLAPS popup, Brightness adjusts LED brightness manually; AUTO uses the PFD’s ambient-light input. A manual adjustment turns AUTO off. Verify the physical LED brightness; no recommended percentage is specified.

Finish at the aircraft’s required ground position, with the actuator stopped.

13.5. Diagnostics and calibration reset

Open: MORE / SETTINGS / DIAGNOSTICS / FLAPS. Use REFRESH to request current status. Check Status, Motor current, State, and Active faults.

Cropped DIAGNOSTICS - FLAPS with simulated OK protocol v1, 0.0 A current, stopped and calibrated state, and no active faults.

UI illustration: diagnostic status and faults. All readings are simulated; 0.0 A is not an installation acceptance limit. Action controls are below the crop.

OK - PROTOCOL v1 identifies a fresh diagnostic response without an active fault or uncalibrated flag. UNCALIBRATED requires calibration; WAITING / OFFLINE or NO PROTOCOL V1 RESPONSE require checking power, CAN communication and firmware. HARDWARE detection alone does not verify the diagnostic protocol. Values retained on an OFFLINE screen are not current readings.

13.6. Fault lookup

Use the text in Active and Latest event to find the indication below. The checks are starting points, not a diagnosis of the installation.

Flaps fault indications

Indication

Meaning and first checks

MOTOR DISCONNECTED

Includes OPEN LOAD (also OUT1/OUT2) and OFF-STATE DIAGNOSTIC. Open load or little movement with low current was detected. Check motor connections, continuity and supply; this does not prove the motor is unplugged.

SOFTWARE CURRENT LIMIT

Motor current protection latched. Check for binding, end-stop contact, excessive load or motor-wiring problems before resetting.

OVERCURRENT

Includes OUT1/OUT2 HIGH/LOW. Driver overcurrent was detected. Check for shorts, damaged motor wiring, binding or overload.

MOVE TIMEOUT

The commanded position was not reached before the movement timeout. Check actual travel, binding, motor operation, feedback and calibration.

UNDERVOLTAGE

The motor driver reported low supply voltage. Check supply and return connections, including voltage drop during movement.

OVERVOLTAGE

The motor driver reported excessive supply voltage. Check the controller supply and aircraft electrical installation.

THERMAL SHUTDOWN

Motor-driver temperature protection operated. Allow cooling and inspect load, binding and controller cooling before further movement.

SPI ERROR

Communication with the motor-driver chip failed. This is internal driver communication, not a CAN-bus error. Check controller power; persistent errors require controller service.

DRIVER CONFIG INVALID

Required motor-driver configuration could not be verified. Check controller power; use the recovery procedure below. Persistent failure requires controller service.

LATCHED DRIVER FAULT

Also CONTROLLER FAULT ACTIVE. Read the accompanying indications and register values; these summary messages alone do not identify the cause.

Motor safety-limit abort in Latest event

The controller reported a software position-bound stop. Review feedback and calibration against the normal 50–850 target bounds and permitted aircraft travel; do not bypass the bound.

MOTION HELD

Movement is inhibited after a fault. Read and resolve the accompanying cause before acknowledging it and commanding movement again.

RAISED and CLEARED describe the latest recorded transition, not the present state of every fault. Refresh and recheck Active. Motor power-on reset, Motor current limit (driver current regulation), and Motor driver-off pin can appear as events without an active fault; they do not by themselves establish a defective controller. A current appended to Software current limit is the recorded trip current, not an installation setting. Repeated unexpected reset events still require a supply/controller check.

13.6.1. Read raw driver values

The Registers row uses hexadecimal: FAULT … / STATUS1 … / STATUS2 …. The following values apply only to the raw FAULT byte, not to STATUS1, STATUS2, or the trim controller’s fault number.

FAULT bit value (hex)

Meaning

01

Open load

02

Thermal shutdown

04

Overcurrent

08

Undervoltage

10

Overvoltage

20

Latched driver fault

40

Power-on reset indication; not an active fault by itself

80

Motor-driver SPI error

Several bits can be present together: FAULT 0C contains 08 + 04, meaning undervoltage and overcurrent indications. A detail 0x… suffix is additional event data, not a separate fault number. Record the full named indication and all three register values when requesting support; do not apply this table’s meaning to a STATUS1 or STATUS2 value.

FAULT 00 only means that raw register has no bits set. Controller-held faults such as a software current limit or movement timeout can still be active; use the refreshed Active field to check them.

13.6.2. Recover and recheck

For FAULT, read the active fault and latest event before continuing. Resolve binding, wiring, supply, motor or driver problems as indicated. CLEAR ERR clears latched errors and REINITIALIZE reinitializes the motor driver; both are recovery actions that stop movement, not evidence that its cause is repaired. Use them with the mechanism stopped and appropriate installation/service guidance, then confirm the result and refresh the actual status. Do not repeat movement against a persistent fault.

ERASE CALIBRATION in FLAPS SERVO SETUP is not needed for ordinary capture or recalibration. Its two confirmations erase all captured positions and re-enable the optional -1 position. Use it only when intentionally starting over; then select the required arrangement and repeat the complete calibration, retention and ground checks before normal operation.