Complete Initial installation first. The Datahub connects wired controls, digital warning inputs, and supported radio/transponder interfaces to the SD-10 over CAN. Complete this chapter before AI PC setup.
With tandem displays, configure from the PFD and verify the received settings and indications on both displays. Update the shared Datahub once.
7.1. Connect and confirm detection
Complete power, CAN, control, and connected-equipment wiring according to the Datahub hardware manual.
Open: MORE / SETTINGS / CONFIGURATION / HARDWARE.
Find Datahub and select Schochman Datahub if needed.
Wait for green ONLINE or a green SNxxxxxx serial number.
Reopen HARDWARE and confirm the selection and status.
UI illustration: detected Datahub. The serial and status are examples.
If a connected Datahub is detected while the model is NONE, the application enables it automatically and reports Datahub detected. A message that its configuration could not be saved permanently requires attention before continuing. For OFFLINE, check power and CAN wiring.
7.2. Check and update firmware
Open: MORE / SETTINGS / UPDATES / DEVICES UPDATE. Use the Datahub row. Internet access and login on the SD-10 are required to download firmware.
Read the reported firmware v….
If an update is available, select UPDATE, then Update and Confirm in the two prompts. The first warns that communications will temporarily stop. Both prompts restrict the update to ground use.
Keep the Datahub and display powered through download, upload, and restart.
Wait for the returned firmware version and recheck detection in HARDWARE.
UI illustrations: firmware update. Versions and progress are fictional examples.
Upload complete – waiting for device restart is an intermediate state. Verify the installed version after restart. Firmware already up to date means no update is needed; a disabled UPDATE button alone does not confirm this.
7.3. Configure connected radio and transponder
Complete this setup on the connected equipment before checking it in EFIS. With tandem displays, configure each shared radio or transponder once.
7.3.1. ATR833-II radio
The radio needs no separate remote-control enable setting. Connect its remote-control RS232 interface according to the hardware manual. EFIS starts communication automatically through the Datahub.
7.3.2. TRT800H-OLED transponder
Use transponder software 6.3 or later. The GPS/INT setting is separate; leave the existing GPS/ADS-B configuration unchanged.
On the ground, switch on the transponder and note its software version. Select the correct aircraft record if a record list appears.
Select STBY. Hold ID until ENTER SETUP appears, then release it.
Use MODE to pass the other setup items without changing them and reach the remote-interface setting.
With the rotary knob, select Port 2: REMOTE TEST. On software 6.3/6.4, the setting is labelled Remote Hd: TEST or REMOTE Header: Test.
Continue with MODE to exit setup. Switch the transponder off, then on.
Recheck the saved setting for the selected aircraft record. On the Remote Header version, hold ID in STBY and release it at SHOW SETUP. Use MODE to find the summary showing Remote Hd.: TEST.
Keep the selected aircraft’s address, category, flight ID, and other installation settings unchanged. Remote-interface settings belong to the aircraft record; recheck them if a different record is selected.
UI illustration: Remote Header label variant with Test selected. Record 1 is an example.
7.4. Check connected radio and transponder
In MORE / SETTINGS / CONFIGURATION / HARDWARE, select the model for each installed, EFIS-connected device:
VHF COM Radio: f.u.n.k.e. ATR833-II.
Transponder: f.u.n.k.e. TRT800H-OLED.
Use NONE for a device that is absent or not connected for EFIS control.
Selections save automatically. Confirm green ONLINE for each configured device. Radio and XPDR selection requires the Datahub to be enabled.
UI illustration: connected avionics. Select only equipment actually installed.
Check that received values match the connected equipment’s own display. Detailed radio and transponder operation will be covered later. N/A with NONE does not establish a working connection to an installed device.
7.5. Identify wired controls
Buttons and switches are supplied by the installer. Use momentary controls for navigation, Select, and AI; use a spring-return, centre-off rocker for flaps. For the current AP input handling, a maintained switch is recommended; see the AP check below.
Left-side navigation, Select, and AI inputs operate the PFD. Their right-side equivalents operate the MFD. Both AP inputs are handled by the PFD. Only the left flap inputs command flaps. Right flap inputs and both PTT inputs are unused.
The table uses the firmware input names and joystick connector pin numbers, not processor GPIO numbers. Use the hardware manual to identify the connector.
Input |
Left |
Right |
Function |
|---|---|---|---|
Pitch down |
1 |
14 |
Previous focused item. With value/zoom adjustment attached: increase the value or zoom in. |
Pitch up |
2 |
15 |
Next focused item. With value/zoom adjustment attached: decrease the value or zoom out. |
Roll left |
3 |
16 |
Previous main tab. An open popup may handle or block this action. |
Roll right |
4 |
17 |
Next main tab. An open popup may handle or block this action. |
PTT |
5 |
18 |
Unused for this installation. Leave unconnected. |
Flaps down |
9 |
21 |
Left: next configured flap position. Right: unused. |
Flaps up |
10 |
22 |
Left: previous configured flap position. Right: unused. |
COM_SWAP / Select |
11 |
23 |
Activates the focused control. Its menu function is Select/Confirm. |
Blue / AP |
12 |
24 |
Toggles autopilot engagement when the input changes. Both inputs act through the PFD. |
Green / AI Button |
13 |
25 |
Hold to capture speech; release to finish. Requires AI PC setup. |
Directions and Select act once per press; release between steps. The DIGITAL screen configures separate warning inputs DIN1–DIN4, not these controls.
7.7. Verify other wired controls
7.7.1. Flap rocker
Use the flap installation’s ground-test procedure, with the flap mechanism clear. The flap controller must be configured and connected.
After startup or a communication interruption, leave both flap inputs neutral for at least 0.5 seconds before testing.
From an intermediate configured position, press Flaps down, release, then press Flaps up and release. Each press must request one adjacent configured position in the correct direction. Check the indication and actual flap movement. Holding the rocker does not step repeatedly.
Both inputs active together do not issue a new position command. Right-side flap inputs currently have no assigned action.
Restore the installation’s required ground position when finished. Complete flap configuration first if positions or movement cannot yet be verified.
7.7.2. AP switch
Use the autopilot installation’s ground-test procedure, with controls and control surfaces clear. AP engagement can move the aircraft controls.
The current code toggles AP on each input change. A momentary button would toggle on press and toggle again on release, so a maintained switch is recommended. Switch position does not indicate AP ON/OFF; always read the displayed AP state. The first detected change after application startup is ignored separately for each AP input.
After that initial change, operate each installed AP switch separately and watch the PFD’s AP indication change. Both left and right AP inputs act through the PFD. Confirm AP is disengaged at the end. If servo configuration or communication prevents engagement, complete that part of the check during autopilot commissioning; do not treat an inhibited engagement as a proven wiring fault.
7.8. Configure optional digital warning inputs
After communication loss, warnings keep using the last received input states indefinitely. A previously normal input can remain warning-free even if the physical condition changes.
Open: MORE / SETTINGS / CONFIGURATION / DATAHUB / DIGITAL.
UI illustration: DIGITAL is available. ANALOG, RELAY, and PWM are disabled.
For each connected warning input:
Select the wired Pin selection: DIN1 / DSUB-IO_P15, DIN2 / DSUB-IO_P14, DIN3 / DSUB-IO_P13, or DIN4 / DSUB-IO_P12.
Choose ERROR INDICATOR in Configuration mode. Use NONE when no warning is required from that input.
Set Name of the pin to the warning text, up to 18 characters.
Observe Current state while the connected signal changes. HIGH / LOW shows the raw input state. NO DATA means no digital input data has been received; NOT CONFIGURED means the Datahub is not enabled.
Set Inverted logic from the actual signal: NO activates the warning at HIGH; YES activates it at LOW. Confirm both normal and warning states.
Choose Indicator location: STATUS_BAR, SYNTHETIC_VISION, or POPUP.
UI illustration: unsaved warning setup. Use the installation’s pin, name, and logic.
7.9. Preview, save, and verify warnings
Select PREVIEW to force the selected warning for ten seconds, even with a normal input. The button shows the countdown. This does not verify wiring or polarity. A POPUP has a separate 30-second lifetime from opening; preview expiry or a cleared input does not close it.
Select SAVE for the selected pin. Wait for Saved. Unable to save can leave the attempted settings active in warning evaluation. Resolve the failure, save successfully, and recheck the settings before continuing. DISCARD restores editor fields only; it does not undo a failed save’s live change.
Repeat for each input, then reopen DIGITAL and check each saved selection.
After preview expires, use CLOSE on any remaining preview popup. Then verify actual normal and warning signals and their indications. These settings are stored on the displays; the Datahub supplies the input states.
UI illustrations: forced warning preview and countdown with a normal input.
UI illustration: reopened saved settings with an example HIGH input.
For POPUP, CLOSE dismisses the message. IGNORE suppresses that pin’s popup for the current application run. Dismissing a popup does not clear the physical warning condition.
With tandem displays, verify every saved pin’s mode, name, inversion, and location on the other display. Run PREVIEW separately on each display and check the real indications on both after preview ends.
7.10. Check diagnostics and completion
Open: MORE / SETTINGS / DIAGNOSTICS / JOYSTICKS. The detail screen is titled DIAGNOSTICS - Joysticks.
UI illustration: PFD control-message communication. The status is simulated.
On the PFD, OK indicates recent control-message reception. On the MFD, OK is reported whenever the Datahub is configured, even without fresh control messages. Verify MFD reception using HARDWARE status and actual right-side control responses.
On the PFD, confirm a status beginning with OK.
On each display, confirm Datahub detection in HARDWARE and the returned firmware version after an update.
Confirm the configured radio/XPDR connections and real warning-input behavior.
With tandem displays, repeat status and received-setting checks on both.
Continue to AI PC for AI Button listening, audio levels, and ATC capture.
The PFD’s OK diagnostic does not prove every control, warning input, or audio connection works.
7.11. If setup does not complete
Indication |
Action |
|---|---|
Datahub OFFLINE |
Check power and CAN wiring. Recheck HARDWARE and JOYSTICKS diagnostics. |
DATAHUB or avionics selection unavailable |
Confirm Schochman Datahub is selected in HARDWARE. |
Radio or XPDR OFFLINE |
Check the selected model, equipment power, and its Datahub interface wiring. For the transponder, also check software 6.3 or later and Port 2 REMOTE TEST in the selected aircraft record. |
NO DATA or a state that does not change |
Recheck Datahub communication and the selected physical input. HIGH/LOW and warning evaluation retain the last received state. No warning after communication loss does not confirm a normal condition. |
Warning active in the normal condition |
Wait for PREVIEW to end and CLOSE any remaining popup. Then check signal state and Inverted logic against the installation wiring. |
Unable to save |
Attempted settings can still affect warnings. DISCARD resets editor fields only. Resolve the save failure, save successfully, and recheck the settings. |
Warning missing |
Check mode, indicator location, saved values, actual signal, and inversion. For POPUP, check whether IGNORE was used during this application run. |
Settings differ between displays |
Check both displays’ Ethernet connection, then reopen DIGITAL and compare all fields for the same pin. Do not assume reception from a local Saved message. |
Firmware update failed or version missing |
Record the error. Check connection and retry only on the ground. Verify the returned installed version before continuing. |