2. Connectors

2.1. Figure - connectors location

Front and rear views locating the EMS connectors

2.2. Connector DSUB-MAIN

2.2.1. Connector DSUB-MAIN - Description

This connector provides EMS power and connects the EMS to the system CAN bus. Leave address inputs on pins 3 and 5 unconnected. They are reserved for future firmware support.

Mechanical Characteristics

  • Connector type: DE-9 (9-pin, 2-row D-Sub)

  • Gender: Male (pins on device)

  • Mounting: Panel-mounted with integrated screw-lock holes

Secure each installed D-Sub plug with screw-lock fasteners. Standard D-Sub jack screws are suitable.

2.2.2. Figure - Connector DSUB-MAIN - pinout

Nine-pin DSUB-MAIN connector pin positions

2.2.3. Table - Connector DSUB-MAIN - pinout

Number

Label

Description

1

CAN_H

CAN bus HIGH

2

CAN_L

CAN bus LOW

3

ADDR1

Address input 1 (reserved)

4

GND

Ground

5

ADDR2

Address input 2 (reserved)

6

GND

Ground

7

BAT_P

Battery primary

8

BAT_S

Battery secondary

9

GND

Ground

2.3. Connectors DSUB-ECU-A and DSUB-ECU-B

2.3.1. Connectors DSUB-ECU-A and DSUB-ECU-B - Description

The DSUB-ECU-A and DSUB-ECU-B connectors are used to connect the device to the Rotax ECU engine CAN-bus system.

These connectors provide independent connections to Rotax ECU display CAN lanes A and B, allowing the EFIS to receive engine and system data from both channels.

2.3.2. Figure - Connectors DSUB-ECU-A and DSUB-ECU-B - pinout

Nine-pin connector pin positions

2.3.3. Table - Connectors DSUB-ECU-A and DSUB-ECU-B - pinout

Number

Label

Description

1

CAN_H

ECU CAN bus HIGH

2

CAN_L

ECU CAN bus LOW

3

DNC

Do not connect

4

DNC

Do not connect

5

DNC

Do not connect

6

GND

Ground

7

BAT_P

Battery primary (disconnected if power is provided via DSUB-MAIN)

8

BAT_S

Battery secondary (disconnected if power is provided via DSUB-MAIN)

9

GND

Ground

2.4. Connector DSUB-EMS-1

2.4.1. Connector DSUB-EMS-1 - Description

The DSUB-EMS-1 connector is used to connect engine monitoring system (EMS) sensors directly to the device in installations where a CAN-based ECU is not used, or where additional sensors are required beyond those provided by the external ECU system.

Even in CAN ECU-equipped aircraft, selected EMS sensors may still be connected via this connector, as not all engine or airframe parameters are available through the ECU CAN-bus.

The connector provides multiple sensor supply rails (12 V, 5 V, and GND) and dedicated signal inputs to support a wide range of analog and digital engine sensors.

Supported sensor input types on DSUB-EMS-1 include:

  • 3× resistive sensor inputs

  • 2× voltage-based sensor inputs

  • 1× interrupt-based input

  • 1× shunt measurement input

2.4.2. Figure - Connector DSUB-EMS-1 - pinout

Twenty-five-pin DSUB-EMS-1 connector pin positions

2.4.3. Table - Connector DSUB-EMS-1 - pinout

Number

Label

Description

1

GND

Ground

2

D1-P2-VOL

Voltage based sensor signal

3

12V

Power supply for sensor

4

5V

Power supply for sensor

5

GND

Ground

6

D1-P6-VOL

Voltage based sensor signal

7

12V

Power supply for sensor

8

5V

Power supply for sensor

9

12V

Power supply for sensor

10

D1-P10-RES

Resistance based sensor signal

11

GND

Ground

12

12V

Power supply for sensor

13

D1-P13-RES

Resistance based sensor signal

14

GND

Ground

15

12V

Power supply for sensor

16

D1-P16-RES

Resistance based sensor signal

17

GND

Ground

18

D1-P18-INT

Fuel flow pulse input (EFIS configuration pin DSUB_25_P18).

19

VIN

Unregulated input supply (reserved). Leave unconnected.

20

GND

Ground

21

SHNT-B

Shunt resistor pin

22

SHNT-A

Shunt resistor pin

23

12V

Power supply for sensor

24

DNC

Do not connect

25

GND

Ground

2.5. Connector DSUB-EMS-2

2.5.1. Connector DSUB-EMS-2 - Description

The DSUB-EMS-2 connector is used to connect additional engine monitoring sensors, primarily those requiring thermocouple and multi-channel analog inputs.

This connector is typically used in installations where detailed exhaust gas and electrical measurements are required, either in non-ECU CAN configurations or as a supplement to ECU CAN-based engine data, as ECU systems do not provide all available temperature and electrical parameters.

Supported sensor input types on DSUB-EMS-2 include:

  • 6× 2-pin inputs for thermocouple sensors (e.g. EGT temperature probes)

  • 2× resistive sensor inputs

  • 2× current-based sensor inputs

  • 2× voltage-based sensor inputs

  • 1× interrupt-based input

2.5.2. Figure - Connector DSUB-EMS-2 - pinout

Thirty-seven-pin DSUB-EMS-2 connector pin positions

2.5.3. Table - Connector DSUB-EMS-2 - pinout

Number

Label

Description

1

GND

Ground

2

D2-P2-CUR

Current based sensor signal

3

D2-P3-VOL

Voltage based sensor signal

4

12V

Power supply for sensor

5

5V

Power supply for sensor

6

GND

Ground

7

D2-P7-CUR

Current based sensor signal

8

D2-P8-VOL

Voltage based sensor signal

9

12V

Power supply for sensor

10

5V

Power supply for sensor

11

DNC

Do not connect

12

DNC

Do not connect

13

DNC

Do not connect

14

EGT6_A

Thermocouple type K - A pin

15

EGT5_A

Thermocouple type K - A pin

16

EGT4_A

Thermocouple type K - A pin

17

EGT3_A

Thermocouple type K - A pin

18

EGT2_A

Thermocouple type K - A pin

19

EGT1_A

Thermocouple type K - A pin

20

GND

Ground

21

D2-P21-RES

Resistance based sensor signal

22

GND

Ground

23

D2-P23-RES

Resistance based sensor signal

24

GND

Ground

25

D2-P25-INT

Interrupt based sensor signal

26

VIN

Unregulated input supply (reserved). Leave unconnected.

27

DNC

Do not connect

28

DNC

Do not connect

29

DNC

Do not connect

30

DNC

Do not connect

31

DNC

Do not connect

32

EGT6_B

Thermocouple type K - B pin

33

EGT5_B

Thermocouple type K - B pin

34

EGT4_B

Thermocouple type K - B pin

35

EGT3_B

Thermocouple type K - B pin

36

EGT2_B

Thermocouple type K - B pin

37

EGT1_B

Thermocouple type K - B pin