2. Connectors
2.1. Figure - connectors location
2.2. Connector DSUB-MAIN
2.2.1. Connector DSUB-MAIN - Description
This connector provides EMS power and connects the EMS to the system CAN bus. Leave address inputs on pins 3 and 5 unconnected. They are reserved for future firmware support.
Mechanical Characteristics
Connector type: DE-9 (9-pin, 2-row D-Sub)
Gender: Male (pins on device)
Mounting: Panel-mounted with integrated screw-lock holes
Secure each installed D-Sub plug with screw-lock fasteners. Standard D-Sub jack screws are suitable.
2.2.2. Figure - Connector DSUB-MAIN - pinout
2.2.3. Table - Connector DSUB-MAIN - pinout
Number |
Label |
Description |
|---|---|---|
1 |
CAN_H |
CAN bus HIGH |
2 |
CAN_L |
CAN bus LOW |
3 |
ADDR1 |
Address input 1 (reserved) |
4 |
GND |
Ground |
5 |
ADDR2 |
Address input 2 (reserved) |
6 |
GND |
Ground |
7 |
BAT_P |
Battery primary |
8 |
BAT_S |
Battery secondary |
9 |
GND |
Ground |
2.3. Connectors DSUB-ECU-A and DSUB-ECU-B
2.3.1. Connectors DSUB-ECU-A and DSUB-ECU-B - Description
The DSUB-ECU-A and DSUB-ECU-B connectors are used to connect the device to the Rotax ECU engine CAN-bus system.
These connectors provide independent connections to Rotax ECU display CAN lanes A and B, allowing the EFIS to receive engine and system data from both channels.
2.3.2. Figure - Connectors DSUB-ECU-A and DSUB-ECU-B - pinout
2.3.3. Table - Connectors DSUB-ECU-A and DSUB-ECU-B - pinout
Number |
Label |
Description |
|---|---|---|
1 |
CAN_H |
ECU CAN bus HIGH |
2 |
CAN_L |
ECU CAN bus LOW |
3 |
DNC |
Do not connect |
4 |
DNC |
Do not connect |
5 |
DNC |
Do not connect |
6 |
GND |
Ground |
7 |
BAT_P |
Battery primary (disconnected if power is provided via DSUB-MAIN) |
8 |
BAT_S |
Battery secondary (disconnected if power is provided via DSUB-MAIN) |
9 |
GND |
Ground |
2.4. Connector DSUB-EMS-1
2.4.1. Connector DSUB-EMS-1 - Description
The DSUB-EMS-1 connector is used to connect engine monitoring system (EMS) sensors directly to the device in installations where a CAN-based ECU is not used, or where additional sensors are required beyond those provided by the external ECU system.
Even in CAN ECU-equipped aircraft, selected EMS sensors may still be connected via this connector, as not all engine or airframe parameters are available through the ECU CAN-bus.
The connector provides multiple sensor supply rails (12 V, 5 V, and GND) and dedicated signal inputs to support a wide range of analog and digital engine sensors.
Supported sensor input types on DSUB-EMS-1 include:
3× resistive sensor inputs
2× voltage-based sensor inputs
1× interrupt-based input
1× shunt measurement input
2.4.2. Figure - Connector DSUB-EMS-1 - pinout
2.4.3. Table - Connector DSUB-EMS-1 - pinout
Number |
Label |
Description |
|---|---|---|
1 |
GND |
Ground |
2 |
D1-P2-VOL |
Voltage based sensor signal |
3 |
12V |
Power supply for sensor |
4 |
5V |
Power supply for sensor |
5 |
GND |
Ground |
6 |
D1-P6-VOL |
Voltage based sensor signal |
7 |
12V |
Power supply for sensor |
8 |
5V |
Power supply for sensor |
9 |
12V |
Power supply for sensor |
10 |
D1-P10-RES |
Resistance based sensor signal |
11 |
GND |
Ground |
12 |
12V |
Power supply for sensor |
13 |
D1-P13-RES |
Resistance based sensor signal |
14 |
GND |
Ground |
15 |
12V |
Power supply for sensor |
16 |
D1-P16-RES |
Resistance based sensor signal |
17 |
GND |
Ground |
18 |
D1-P18-INT |
Fuel flow pulse input (EFIS configuration pin |
19 |
VIN |
Unregulated input supply (reserved). Leave unconnected. |
20 |
GND |
Ground |
21 |
SHNT-B |
Shunt resistor pin |
22 |
SHNT-A |
Shunt resistor pin |
23 |
12V |
Power supply for sensor |
24 |
DNC |
Do not connect |
25 |
GND |
Ground |
2.5. Connector DSUB-EMS-2
2.5.1. Connector DSUB-EMS-2 - Description
The DSUB-EMS-2 connector is used to connect additional engine monitoring sensors, primarily those requiring thermocouple and multi-channel analog inputs.
This connector is typically used in installations where detailed exhaust gas and electrical measurements are required, either in non-ECU CAN configurations or as a supplement to ECU CAN-based engine data, as ECU systems do not provide all available temperature and electrical parameters.
Supported sensor input types on DSUB-EMS-2 include:
6× 2-pin inputs for thermocouple sensors (e.g. EGT temperature probes)
2× resistive sensor inputs
2× current-based sensor inputs
2× voltage-based sensor inputs
1× interrupt-based input
2.5.2. Figure - Connector DSUB-EMS-2 - pinout
2.5.3. Table - Connector DSUB-EMS-2 - pinout
Number |
Label |
Description |
|---|---|---|
1 |
GND |
Ground |
2 |
D2-P2-CUR |
Current based sensor signal |
3 |
D2-P3-VOL |
Voltage based sensor signal |
4 |
12V |
Power supply for sensor |
5 |
5V |
Power supply for sensor |
6 |
GND |
Ground |
7 |
D2-P7-CUR |
Current based sensor signal |
8 |
D2-P8-VOL |
Voltage based sensor signal |
9 |
12V |
Power supply for sensor |
10 |
5V |
Power supply for sensor |
11 |
DNC |
Do not connect |
12 |
DNC |
Do not connect |
13 |
DNC |
Do not connect |
14 |
EGT6_A |
Thermocouple type K - A pin |
15 |
EGT5_A |
Thermocouple type K - A pin |
16 |
EGT4_A |
Thermocouple type K - A pin |
17 |
EGT3_A |
Thermocouple type K - A pin |
18 |
EGT2_A |
Thermocouple type K - A pin |
19 |
EGT1_A |
Thermocouple type K - A pin |
20 |
GND |
Ground |
21 |
D2-P21-RES |
Resistance based sensor signal |
22 |
GND |
Ground |
23 |
D2-P23-RES |
Resistance based sensor signal |
24 |
GND |
Ground |
25 |
D2-P25-INT |
Interrupt based sensor signal |
26 |
VIN |
Unregulated input supply (reserved). Leave unconnected. |
27 |
DNC |
Do not connect |
28 |
DNC |
Do not connect |
29 |
DNC |
Do not connect |
30 |
DNC |
Do not connect |
31 |
DNC |
Do not connect |
32 |
EGT6_B |
Thermocouple type K - B pin |
33 |
EGT5_B |
Thermocouple type K - B pin |
34 |
EGT4_B |
Thermocouple type K - B pin |
35 |
EGT3_B |
Thermocouple type K - B pin |
36 |
EGT2_B |
Thermocouple type K - B pin |
37 |
EGT1_B |
Thermocouple type K - B pin |