Typical EMS wiring diagram for a Rotax 912 iS installation

This figure provides a typical wiring overview for the Schochman Engine Monitoring System, showing the most common connections used in a standard ROTAX 912 iS installation: power + CAN bus, two dedicated ECU CAN-bus links, and selected direct EMS sensor inputs.

Power and CAN bus (DSUB-MAIN)

  • The EMS is powered from the aircraft electrical system via DSUB-MAIN. Connect the aircraft power feed to the EMS power input (BAT_P / BAT_S as applicable) and connect GND to the aircraft ground/return.

  • The figure also shows the EMS connected to the system CAN-BUS trunk using CAN_H and CAN_L. Use a twisted pair for CAN_H/CAN_L and keep stubs short (EMS connected as a node on the main CAN line).

ECU CAN integration (DSUB-ECU-A and DSUB-ECU-B)
The diagram shows two independent CAN-bus interfaces connected to the ROTAX ECU communication lanes:

  • DSUB-ECU-A → ROTAX ECU lane A

  • DSUB-ECU-B → ROTAX ECU lane B

Supply and fit one 120 Ω termination resistor across CAN_H and CAN_L at the EMS end of each ECU display CAN link. The Rotax ECU provides the termination at the other end of each link.

Direct sensor integration (DSUB-EMS-1)
In addition to ECU CAN data, the figure shows selected sensors connected directly to DSUB-EMS-1 for parameters that may not be available from the ECU CAN-bus alone. In the illustrated example, these are:

  • fuel pressure sensor, connected as a voltage-based sensor input with power and ground,

  • left and right fuel quantity sensors, connected as resistive sensor inputs,

  • external 1 mΩ nominal shunt, connected to the dedicated shunt inputs. Select a shunt rated for the aircraft and engine installation's electrical system and expected current.

Important note about omitted wiring
In this typical overview, non-EMS-related wiring is intentionally not shown for readability. In a real installation, the engine, ECUs, and all connected sensors still require their full installation-specific wiring as applicable, including their own power supply, grounding, harnessing, and any other connections required by the relevant manufacturer documentation.