2. Operation
2.1. Direct operation
2.1.1. Figure - Front view of the device
2.1.2. Position indicators
The controller uses 5 RGB LEDs to indicate flap status and system state.
On power-up, the LEDs perform a short startup sequence, displaying red → green → blue → white, each for approximately 1 second, to confirm proper LED operation. After this sequence, the LEDs switch to normal status display.
During normal operation:
Green marks the selected target.
Red marks the calibrated preset nearest the measured position when that preset differs from the target.
Blue marks the other enabled presets.
If the negative-flaps position is disabled, its corresponding LED remains off
Motor driver faults, motor disconnection, movement timeouts, and uncalibrated movement requests can trigger fault flashing. During fault flashing, the green target and any separate red position indicator stay lit while the other enabled LEDs flash red.
LED brightness follows the user-configured setting (0–100%, default 10%).
2.1.3. Two way switch
The controller supports a momentary two-way (Up / Down) switch for manual flap control.
Each switch action is detected on a press-and-release cycle and includes an internal debounce delay to prevent unintended multiple commands.
Switch behavior:
Pressing Up commands the next smaller flap position
Pressing Down commands the next larger flap position
The selected position is limited to enabled flap positions only
If the negative-flaps position is disabled, the controller will not step below the first enabled position
Safety and status behavior:
If flap calibration is active or incomplete, switch inputs do not move the actuator and instead trigger an uncalibrated alert
After some faults, the first press and release of the rocker can retry movement toward the previously selected preset. The selected preset stays the same during the retry.