2. Connectors

2.1. Figure - connectors location

Front and rear views locating the Datahub connectors

2.2. Connector DSUB-MAIN

2.2.1. Connector DSUB-MAIN - Description

This connector provides Datahub power and connects the Datahub to the system CAN bus. The current firmware does not use the address inputs. Leave pins 3 and 5 unconnected.

Mechanical Characteristics

  • Connector type: DE-9 (9-pin, 2-row D-Sub)

  • Gender: Male (pins on device)

  • Mounting: Panel-mounted with integrated screw-lock holes

Secure each installed D-Sub plug with screw-lock fasteners. Standard D-Sub jack screws are suitable.

2.2.2. Figure - Connector DSUB-MAIN - pinout

Nine-pin DSUB-MAIN connector pin positions

2.2.3. Table - Connector DSUB-MAIN - pinout

Number

Label

Description

1

CAN_H

CAN bus HIGH

2

CAN_L

CAN bus LOW

3

ADDR_1

Address input 1 (reserved)

4

GND

Ground

5

ADDR_2

Address input 2 (reserved)

6

GND

Ground

7

BAT_P

Battery primary

8

BAT_S

Battery secondary

9

GND

Ground

2.3. Connectors DSUB-RS232-A and DSUB-RS232-B

2.3.1. Connectors RS232 - Description

The DSUB-RS232-A and DSUB-RS232-B connectors provide serial RS-232 communication interfaces for integration of supported third-party avionics devices into the Schochman ecosystem. Each connector exposes a minimal RS-232 signal set consisting of transmit, receive, and ground lines and is intended exclusively for point-to-point device communication.

At present, the supported devices are:

  • DSUB-RS232-A — Dedicated interface for ATR833-II VHF radio

  • DSUB-RS232-B — Dedicated interface for TRT800H-OLED transponder

Only the specified devices are supported; compatibility with other RS-232 equipment is in development.

Mechanical Characteristics

  • Connector type: DE-9 (9-pin, 2-row D-Sub)

  • Gender: Male (pins on device)

  • Mounting: Panel-mounted with integrated screw-lock holes

Secure each installed D-Sub plug with screw-lock fasteners. Standard D-Sub jack screws are suitable.

2.3.2. Figure - Connectors RS232 - pinout

Nine-pin DSUB-RS232-A and DSUB-RS232-B connector pin positions

2.3.3. Table - Connectors RS232 - pinout

Number

Label

Description

1

DNC

Do not connect

2

DNC

Do not connect

3

DNC

Do not connect

4

RXD

RS232-RXD

5

TXD

RS232-TXD

6

GND

Ground

7

DNC

Do not connect

8

DNC

Do not connect

9

GND

Ground

2.4. Connector DSUB-CAN

2.4.1. Connector DSUB-CAN - Description

This secondary CAN-bus interface is reserved for future expansion. Leave DSUB-CAN unconnected in current installations unless updated Schochman documentation specifies its use.

Mechanical Characteristics

  • Connector type: DE-9 (9-pin, 2-row D-Sub)

  • Gender: Male (pins on device)

  • Mounting: Panel-mounted with integrated screw-lock holes

Secure each installed D-Sub plug with screw-lock fasteners. Standard D-Sub jack screws are suitable.

2.4.2. Figure - Connector DSUB-CAN - pinout

Nine-pin DSUB-CAN connector pin positions

2.4.3. Table - Connector DSUB-CAN - pinout

Number

Label

Description

1

CAN_H

CAN bus HIGH

2

CAN_L

CAN bus LOW

3

DNC

Do not connect

4

DNC

Do not connect

5

DNC

Do not connect

6

GND

Ground

7

BAT_P

Battery primary

8

BAT_S

Battery secondary

9

GND

Ground

2.5. Connector DSUB-IO

2.5.1. Connector DSUB-IO - Description

DSUB-IO is optional. The current firmware reads digital inputs DIN1 through DIN4. The analog inputs, switched supply outputs, and relay contacts are reserved for future firmware support. The switched outputs follow the Datahub input supply when energized.

Mechanical Characteristics

  • Connector type: DA-15 (15-pin, 2-row D-Sub)

  • Gender: Male (pins on device)

  • Mounting: Panel-mounted with integrated screw-lock holes

Secure each installed D-Sub plug with screw-lock fasteners. Standard D-Sub jack screws are suitable.

2.5.2. Figure - Connector DSUB-IO - pinout

Fifteen-pin DSUB-IO connector pin positions

2.5.3. Table - Connector DSUB-IO - connector pinout

Number

Label

Description

1

GND

Ground

2

OUT3_NO

Relay 3 - normally open

3

OUT3_C

Relay 3 - common

4

OUT3_NC

Relay 3 - normally closed

5

OUT4_NO

Relay 4 - normally open

6

OUT4_C

Relay 4 - common

7

AIN_2

Analog input 2

8

AIN_1

Analog input 1

9

OUT1_BAT

Switched supply output 1

10

OUT2_BAT

Switched supply output 2

11

OUT3_BAT

Switched supply output 3

12

DIN4

Digital input 4

13

DIN3

Digital input 3

14

DIN2

Digital input 2

15

DIN1

Digital input 1

2.6. Connector DSUB-JOYSTICKS

2.6.1. Connector DSUB-JOYSTICKS - Description

The DSUB-JOYSTICKS connector is used to connect up to two control sticks or joystick-style input devices for user interaction with the Schochman EFIS application. The connected inputs are used for menu navigation, selection, and control of various application functions.

The connector is designed to be compatible with multi-button aviation stick grips, such as military-style grips, but it may also be used with custom or third-party devices. Each input operates as a digital discrete input activated by shorting the corresponding signal to ground.

Designed for https://infinityaerospace.com/product/featured/military-style-stick-grips/.

Mechanical Characteristics

  • Connector type: DB-25 (25-pin, 2-row D-Sub)

  • Gender: Male (pins on device)

  • Mounting: Panel-mounted with integrated screw-lock holes

Secure each installed D-Sub plug with screw-lock fasteners. Standard D-Sub jack screws are suitable.

2.6.2. Figure - Connector DSUB-JOYSTICKS - pinout

Twenty-five-pin DSUB-JOYSTICKS connector pin positions

2.6.3. Table - Connector DSUB-JOYSTICKS - pinout

Number

Label

Description

1

DOWN_L

EFIS navigation - DOWN - PFD

2

UP_L

EFIS navigation - UP - PFD

3

LEFT_L

EFIS navigation - LEFT - PFD

4

RIGHT_L

EFIS navigation - RIGHT - PFD

5

RED_L

Red button - PFD

6

GND

Ground

7

GND

Ground

8

GND

Ground

9

FLAP_D_L

Flap control - DOWN - PFD

10

FLAP_U_L

Flap control - UP - PFD

11

ENTER_L

EFIS navigation - ENTER - PFD

12

BLUE_L

Blue button - PFD

13

AI_L

AI button - PFD

14

DOWN_R

EFIS navigation - DOWN - MFD

15

UP_R

EFIS navigation - UP - MFD

16

LEFT_R

EFIS navigation - LEFT - MFD

17

RIGHT_R

EFIS navigation - RIGHT - MFD

18

RED_R

Red button - MFD

19

GND

Ground

20

GND

Ground

21

FLAP_D_R

Flap control - DOWN - MFD

22

FLAP_U_R

Flap control - UP - MFD

23

ENTER_R

EFIS navigation - ENTER - MFD

24

BLUE_R

Blue button - MFD

25

AI_R

AI button - MFD