5. Mounting Procedure
The unit is designed to be mounted to a rigid mounting plate using a manufacturer-defined mounting interface, as illustrated in the installation figure.
The unit shall be secured to the mounting plate using four M3 screws, washers and M3 self-locking nuts, which are installed through the mounting holes provided in the unit enclosure, as shown in the applicable figure.
The unit shall be installed in accordance with the mounting hole pattern and dimensions specified in the applicable installation drawing. During installation, proper seating of the unit against the mounting plate shall be ensured to provide mechanical stability and correct positioning of the unit.
The installation shall ensure:
secure mechanical attachment of the unit to the mounting plate,
proper alignment of the unit with respect to the mounting surface,
compatibility with the mounting hole pattern shown in the installation figure.
5.1. Figure - AHRS Mounting Hole Locations and Spacing
All products designed for installation on a flat base plate, including EMS, Datahub, AHRS, and Audio Multiplexer units, share a common mounting footprint and overall base dimensions.
Due to this standardized mechanical interface, the units are mechanically compatible for vertical stacking when installed on the same base plate. This allows multiple units to be mounted directly above each other while maintaining consistent alignment and mounting hole spacing.
The standardized base dimensions and stacking capability are illustrated in the corresponding figure.
5.2. Figure - AHRS Standard Mounting Footprint for Stackable Units
5.3. Figure - AHRS Instrument Panel Mounting Arrangement
5.4. Figure - AHRS Positioning and alignment requirements
The figure shows yaw alignment in the top view and pitch alignment in the side view. The AHRS must be installed so that its internal reference axes match the aircraft reference axes as closely as possible.
Orientation
Install the AHRS with the connectors facing aft (toward the tail). This is the reference orientation used by the system.
Yaw. Viewed from above, align the AHRS parallel to the aircraft centerline.
Roll. Viewed from the front or rear, align the AHRS in roll to the aircraft’s specified lateral reference.
Pitch alignment
Pitch offset can be compensated in the EFIS configuration, however it is strongly recommended to mount the AHRS at 0° pitch (physically level to the aircraft reference) to minimize configuration error and simplify setup.
Use shims/spacers if needed so the mounting face is rigid and the unit sits flat without preload or distortion.
Additional installation notes (recommended)
Rigid structure: Mount to a stiff plate or structural element; avoid thin flexible panels that can vibrate or “oil-can,” which can degrade attitude quality.
Avoid local magnetic / electrical disturbances: Keep the AHRS away from high-current wiring, contactors, alternator/starter cables, ignition components, loudspeakers, and permanent magnets.
Vibration & strain relief: Provide proper harness and tubing strain relief so connectors and pneumatic ports are not side-loaded by cable/tube tension.
Serviceability: Leave access to connectors and tubing for leak checks, maintenance, and removal without having to disturb unrelated systems.